---
title: AQL sampling for machined parts (ANSI/ASQ Z1.4) | FactoryQA
description: "How to read ANSI/ASQ Z1.4 AQL tables for machined parts: code letters, sample sizes, accept and reject numbers, switching rules and c=0 plans."
image: https://factoryqa.com/hubfs/fqa-og-res-aql-sampling-for-machined-parts.png
---

[![FactoryQA](https://factoryqa.com/hubfs/fqa-logo-white.png)](https://factoryqa.com/)

Features

[**Platform overview**Every module, and how they connect](https://factoryqa.com/feature-overview)[**AI features**Purpose-built AI in every module](https://factoryqa.com/ai-powered-quality-management)[**Integrations**ERP connectors and imports](https://factoryqa.com/integrations)

[**Dashboard**Every module in one scorecard](https://factoryqa.com/products/qualitybi-dashboard)[**Tasks**Every to-do, from every module](https://factoryqa.com/products/task-management)[**Compliance**Readiness for your standard](https://factoryqa.com/products/compliance)[**Quality Plans**Ballooning, PFMEA, control plans, PPAP](https://factoryqa.com/products/quality-plans)[**Documents**Revisions, approvals, sign-offs](https://factoryqa.com/products/document-control)[**Issues**NCRs, CAPAs and SCARs](https://factoryqa.com/products/non-conformance-management)[**Inspection**Sheets, first articles and SPC](https://factoryqa.com/products/inspection-sheets)[**Calibration**Gages, due dates and Gage R&R](https://factoryqa.com/products/calibration-management)[**Preventive Maintenance**Scheduled work orders and repairs](https://factoryqa.com/preventive-maintenance-factoryqa)[**Supplier Quality**Approved suppliers, portal and SCARs](https://factoryqa.com/products/supplier-management)[**Audits**Schedules, checklists and findings](https://factoryqa.com/products/audit-management)[**Learning Management**Courses, quizzes and the training matrix](https://factoryqa.com/products/learning-management-system)[**QMS Generator**Your manual from an interview](https://factoryqa.com/products/qms-generator)

Services

[**Services overview**Certification, consulting and supplier quality](https://factoryqa.com/services)[**Get Certified**Three paths to AS9100, ISO 9001 or ISO 13485: do it yourself, join a workshop, or work 1-1 with a consultant.](https://factoryqa.com/certification-services)[**Certification Workshops**A 9-week, small-group program with 18 expert-led sessions and an AI-built document kit.](https://factoryqa.com/certification-cohorts)[**QMS Consulting**A consultant on your team from training through implementation, internal audit and the registrar audit.](https://factoryqa.com/qms-consulting)[**Supplier Quality Services**Qualification, management, training and security services for your whole supply base.](https://factoryqa.com/supplier-quality-services)

[Pricing](https://factoryqa.com/pricing)

[Log in](https://app.factoryqa.com/auth/login)[Book a demo](https://factoryqa.com/get-a-demo)[Start free](https://app.factoryqa.com/auth/register)

Features[**Platform overview**](https://factoryqa.com/feature-overview)[AI features](https://factoryqa.com/ai-powered-quality-management)[Integrations](https://factoryqa.com/integrations)[Dashboard](https://factoryqa.com/products/qualitybi-dashboard)[Tasks](https://factoryqa.com/products/task-management)[Compliance](https://factoryqa.com/products/compliance)[Quality Plans](https://factoryqa.com/products/quality-plans)[Documents](https://factoryqa.com/products/document-control)[Issues](https://factoryqa.com/products/non-conformance-management)[Inspection](https://factoryqa.com/products/inspection-sheets)[Calibration](https://factoryqa.com/products/calibration-management)[Preventive Maintenance](https://factoryqa.com/preventive-maintenance-factoryqa)[Supplier Quality](https://factoryqa.com/products/supplier-management)[Audits](https://factoryqa.com/products/audit-management)[Learning Management](https://factoryqa.com/products/learning-management-system)[QMS Generator](https://factoryqa.com/products/qms-generator)

Services[**Services overview**](https://factoryqa.com/services)[Get Certified](https://factoryqa.com/certification-services)[Certification Workshops](https://factoryqa.com/certification-cohorts)[QMS Consulting](https://factoryqa.com/qms-consulting)[Supplier Quality Services](https://factoryqa.com/supplier-quality-services)More[**Pricing**](https://factoryqa.com/pricing)[Log in](https://app.factoryqa.com/auth/login)[Book a demo](https://factoryqa.com/get-a-demo)

Supplier quality

# AQL sampling for machined parts (ANSI/ASQ Z1.4)

How to read ANSI/ASQ Z1.4 AQL tables for machined parts: code letters, sample sizes, accept and reject numbers, switching rules and c=0 plans.

FactoryQA quality teamNovember 29, 2026

Search for "AQL table" and you will find charts written for garment importers. The same standard, ANSI/ASQ Z1.4 (equivalent to ISO 2859-1), is used for machined and fabricated parts, with one large difference: aerospace and automotive customers often do not accept the idea of an "acceptable" defect rate at all. This guide shows how to read the tables, and when not to use them.

*1***Lot size**Parts in the lot

*2***Inspection level**Usually general II

*3***Code letter**From the first table

*4***Sample size**From the second table

*5***Accept or reject**Count the defects

Example: 400 parts, level II, AQL 1.0: sample 50, accept on 1, reject on 2

## What AQL means

The acceptance quality limit is the worst process average that a sampling plan will still accept most of the time. An AQL of 1.0 does not mean 1% defects are fine; it describes how the plan behaves. A lot with more defects than that can still be accepted by chance, which is why AQL plans suit low-risk characteristics, not safety or key characteristics.

## Step 1: find the code letter

Use the lot size and the inspection level. General inspection level II is the default.

| Lot size | Code letter (level II) | Sample size |
| --- | --- | --- |
| 26 to 50 | D | 8 |
| 51 to 90 | E | 13 |
| 91 to 150 | F | 20 |
| 151 to 280 | G | 32 |
| 281 to 500 | H | 50 |
| 501 to 1,200 | J | 80 |
| 1,201 to 3,200 | K | 125 |

## Step 2: find the accept and reject numbers

For single sampling under normal inspection, these are the accept (Ac) and reject (Re) numbers for three common cases:

| Code letter (sample) | AQL 1.0 | AQL 2.5 |
| --- | --- | --- |
| H (50) | Ac 1, Re 2 | Ac 3, Re 4 |
| J (80) | Ac 2, Re 3 | Ac 5, Re 6 |
| K (125) | Ac 3, Re 4 | Ac 7, Re 8 |

Example: a lot of 400 parts at level II is code letter H, a sample of 50. At AQL 1.0 you accept the lot with 0 or 1 nonconforming parts and reject it with 2 or more. Always work from the current edition of the standard; where the table shows an arrow, use the plan it points to.

## Switching rules

The standard expects you to react to results. Move from normal to tightened inspection when 2 of 5 consecutive lots are rejected, and back to normal after 5 consecutive lots are accepted. Reduced inspection is available after a run of accepted lots and stable production. A supplier that stays on tightened inspection needs a corrective action, not more sampling (see [how to write a SCAR](https://factoryqa.com/resources/how-to-write-a-scar)).

## Zero acceptance (c=0) plans

Many aerospace, defense and automotive customers require zero-acceptance plans: one nonconforming part in the sample rejects the lot. These plans use smaller samples than Z1.4 for a similar level of protection, and they match a zero-defect expectation. If your customer's requirements name a c=0 plan, it replaces the AQL tables.

## When sampling is the wrong tool

- Key, critical and safety characteristics: inspect 100% or use a validated process control
- Very small lots: sampling gives little confidence; inspect all of them
- Special processes: the result cannot be confirmed by inspecting the part (see [controlling special processes](https://factoryqa.com/resources/controlling-special-processes))
- A new supplier or a changed part: do a first article first

For the whole receiving process, see [incoming inspection for machine shops](https://factoryqa.com/resources/incoming-inspection-procedure).

In FactoryQA, each characteristic on a ballooned drawing carries its own sample size, gage and limits, and the ones flagged Incoming build the part's incoming inspection sheet, graded as readings are entered. You set the sampling from your plan and your customer's requirements; FactoryQA does not include AQL tables. See [Inspection](https://factoryqa.com/products/inspection-sheets).

## Frequently asked questions

### What does AQL mean in sampling?

Acceptance quality limit: the worst process average a sampling plan is designed to accept most of the time. It describes the plan, not a permitted defect rate.

### What sample size do I need for a lot of 500 parts?

Under ANSI/ASQ Z1.4 at general inspection level II, a lot of 281 to 500 parts is code letter H, a sample of 50 for single sampling. Customer requirements may specify a different plan.

### What is a c=0 sampling plan?

A zero-acceptance plan: the lot is rejected if any nonconforming part is found in the sample. It is widely required in aerospace, defense and automotive supply chains.

### Is ANSI Z1.4 the same as ISO 2859-1?

They are equivalent for practical purposes: both descend from MIL-STD-105 and use the same structure of code letters, sample sizes and accept and reject numbers.

### When should I inspect 100% instead of sampling?

For key, critical or safety characteristics, very small lots, a new supplier or part, and whenever your customer requires it.

Keep reading

## More from Resources

[Supplier quality**Supplier quality agreement: a template outline**What a supplier quality agreement should include, with a fifteen-section outline to adapt: change control, nonconformance, SCARs, records and access.](https://factoryqa.com/resources/supplier-quality-agreement-template)[Guide**Gage R&R: how to calculate it and what is acceptable**How to run and calculate a gage R&R study with the average and range method, a worked example, and the AIAG limits: under 10%, 10 to 30%, over 30%.](https://factoryqa.com/resources/gage-r-and-r-guide)[Guide**Calibration intervals: how often to calibrate each gage**How often to calibrate calipers, micrometers and other gages: typical starting intervals, adjusting from as-found data, and out-of-tolerance impact checks.](https://factoryqa.com/resources/calibration-intervals)

## Try it on your own process: start free.

Free plan · Basic $40 · Pro $60 per standard user per month · 14 days of Pro to start

[Start free](https://app.factoryqa.com/auth/register)[Book a demo](https://factoryqa.com/get-a-demo)

![FactoryQA](https://factoryqa.com/hubfs/fqa-logo-white.png)Every quality tool. One connected system.

Product[Features](https://factoryqa.com/feature-overview)[AI features](https://factoryqa.com/ai-powered-quality-management)[Integrations](https://factoryqa.com/integrations)[Pricing](https://factoryqa.com/pricing)

Modules[Quality Plans](https://factoryqa.com/products/quality-plans)[Documents](https://factoryqa.com/products/document-control)[Issues](https://factoryqa.com/products/non-conformance-management)[Inspection](https://factoryqa.com/products/inspection-sheets)[Calibration](https://factoryqa.com/products/calibration-management)

Services[Get Certified](https://factoryqa.com/certification-services)[Certification Workshops](https://factoryqa.com/certification-cohorts)[QMS Consulting](https://factoryqa.com/qms-consulting)[Supplier Quality Services](https://factoryqa.com/supplier-quality-services)

Resources[Guides](https://factoryqa.com/resources)[FAQ](https://factoryqa.com/resources/faq)[Glossary](https://factoryqa.com/resources/quality-glossary)

Company[Contact](https://factoryqa.com/get-a-demo-1)[Help Center](https://app.factoryqa.com/help)[LinkedIn](https://www.linkedin.com/company/factoryqa)[Facebook](https://www.facebook.com/factoryqa)

© 2026 FactoryQA[Privacy Policy](https://factoryqa.com/privacy-policy) · [Terms and Conditions](https://factoryqa.com/terms-and-conditions)

```json
{
  "@context" : "https://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "FactoryQA quality team",
    "url" : "https://factoryqa.com/resources/author/factoryqa-quality-team"
  },
  "dateModified" : "2026-11-29T16:28:13.382Z",
  "datePublished" : "2026-11-29T16:28:13.000Z",
  "headline" : "AQL sampling for machined parts (ANSI/ASQ Z1.4) | FactoryQA",
  "image" : [ "https://factoryqa.com/hubfs/fqa-og-res-aql-sampling-for-machined-parts.png" ],
  "mainEntityOfPage" : {
    "@id" : "https://factoryqa.com/resources/aql-sampling-for-machined-parts",
    "@type" : "WebPage"
  },
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "url" : "https://20847757.fs1.hubspotusercontent-na1.net/hubfs/20847757/264.png"
    },
    "name" : "FactoryQA"
  }
}
```

```json
{
  "@context" : "https://schema.org",
  "@type" : "Article",
  "author" : {
    "@type" : "Organization",
    "name" : "FactoryQA",
    "url" : "https://factoryqa.com/"
  },
  "dateModified" : "2026-11-29",
  "datePublished" : "2026-11-29",
  "description" : "How to read ANSI/ASQ Z1.4 AQL tables for machined parts: code letters, sample sizes, accept and reject numbers, switching rules and c=0 plans.",
  "headline" : "<span id=\"hs_cos_wrapper_name\" class=\"hs_cos_wrapper hs_cos_wrapper_meta_field hs_cos_wrapper_type_text\" style=\"\" data-hs-cos-general-type=\"meta_field\" data-hs-cos-type=\"text\" >AQL sampling for machined parts (ANSI/ASQ Z1.4)</span>",
  "image" : "https://factoryqa.com/hubfs/fqa-og-res-aql-sampling-for-machined-parts.png",
  "mainEntityOfPage" : "https://factoryqa.com/resources/aql-sampling-for-machined-parts",
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "url" : "https://factoryqa.com/hubfs/fqa-logo-white.png"
    },
    "name" : "FactoryQA",
    "url" : "https://factoryqa.com/"
  }
}
```

```json
{
  "@context" : "https://schema.org",
  "@type" : "FAQPage",
  "mainEntity" : [ {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "Acceptance quality limit: the worst process average a sampling plan is designed to accept most of the time. It describes the plan, not a permitted defect rate."
    },
    "name" : "What does AQL mean in sampling?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "Under ANSI/ASQ Z1.4 at general inspection level II, a lot of 281 to 500 parts is code letter H, a sample of 50 for single sampling. Customer requirements may specify a different plan."
    },
    "name" : "What sample size do I need for a lot of 500 parts?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "A zero-acceptance plan: the lot is rejected if any nonconforming part is found in the sample. It is widely required in aerospace, defense and automotive supply chains."
    },
    "name" : "What is a c=0 sampling plan?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "They are equivalent for practical purposes: both descend from MIL-STD-105 and use the same structure of code letters, sample sizes and accept and reject numbers."
    },
    "name" : "Is ANSI Z1.4 the same as ISO 2859-1?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "For key, critical or safety characteristics, very small lots, a new supplier or part, and whenever your customer requires it."
    },
    "name" : "When should I inspect 100% instead of sampling?"
  } ]
}
```